IV Therapy Final Study Set, Questions & Answers List equipment & supplies needed for initiation of IV therapy. - cannulas, tourniquet, clean gloves, site cleansing agent, IV solution, IV tubing, IV pole, extension tubing, dressing
Using _____ gauge and ______ length catheter in the ______vein possible will reduce the mechanical and chemical irritation to the vein wall. - smallest; shortest; largest
Cannulas range from ____ to _____ gauge - 14; 26
Over-the-needle catheters range from ____ to ____ inches in length - 3/4; 3
Butterfly style cannulas range from ____ to ____ inches in length - 3/4; 2
What are the advantages in u sing extension tubing with an over-the-needle cannula? - Loop the tubing away from insertion site, preventing dislodgement and mechanical irritation if pulled.Tubing can be changed away from insertion site. Decreased cannula manipulation and risk of contamination.
General cannula size guidelines:
___ to ___ gauge for children and elderly patients. - 22; 26
General cannula size guidelines:
___ to ___ gauge for medical patients and postoperative surgical patients. - 20; 24
General cannula size guidelines:
___ gauge for surgical patients and for rapid blood administration - 18
General cannula size guidelines:
___ to ____ gauge for trauma patients and those requiring large volumes of fluid rapidly - 14; 16
What is the purpose of the protective caps at each end of the administration set and when should they be removed? - To keep both ends of the tubing sterile until immediately prior to use.
Circle the parts of the IV therapy equipment that must remain sterile: - catheter, tubing insertion spike, stylet (when intact)
A bag of intravenous solution should not hang longer than ___ hours - 24
Intravenous tubing must be changed every ___ to ___ hours - 72; 96
IV sites must be changed every ___ hours - 96
A gauze dressing must be changed every ___ hours - 48
A transparent IV dressing must be changed every ____ - 7 days
Select the appropriate answer for each question: vented or nonvented
What type of administration set (tubing) should be used for nonrigid containers (bags)? - nonvented
Select the appropriate answer for each question: vented or nonvented
What type of administration set (tubing) should be used for solutions supplied in glass containers? - vented
What is macro-drip tubing? - 10 gtt/mL, 15 gtt/mL, 16 gtt/mL, 20 gtt/mL
What is micro-drip tubing? - 60 gtt/mL
To infuse a solution rapidly, use a _____ drip tubing set - macro
To infuse a solution slowly, use a ____ drip tubing set - micro
A physician's order for IV therapy must contain what components? - Date of order, type of fluid solution, volume, length of infusion time
If medication is ordered, identify what additional components to the order must be present - Date, drug, dose, frequency of drug, length of infusion time, dilution strength
True or False:
Prior to initiating IV therapy, the nurse must check the expiration date on the solution and inspect the solution and container for particles, discoloration, cracks, leaks, or punctures. - True
What is time tape? What is the advantage of using time tape? - Monitors IV fluid/medication delivery. You can quickly see if the rate of IV delivery needs to be adjusted.
Should you write directly on the solution container with a marker? Why or why not? - You should not write directly on the IV solution bag as the ink can be absorbed through the IV plastic bag
What is the difference between IV push (IVP) or bolus verses intermittent IV therapy? - IVP is a medication given directly into the IV line and is pushed over a set time identified in IV medication books (i.e. Lasix 10mg over 1 min). A bolus is directly pushed into the IV line at a steady rate (i.e. 50?xtrose)
Do LPNs administer IVP medications? - LPNs do NOT give IVP medications
Describe how to regulate an IV infusing by gravity. - The nurse has to first figure out how many gtt/min to deliver the specific amount of fluid or the dose of medication. Using a watch with a second hand and using a manual controller to either speed up the gtt/min or to slow the gtt/min.
When infusing by gravity, how high should the solution be positioned above the infusion site? - IV bag should be 36 inches above the insertion site
Differentiate between an electronic pump and a controller. - Electronic pump controls IV fluid infusion by a computer. Controller is controlled manually (gravity drip) by the nurse.
True or False An infusion pump will stop administering an IV solution if an IV infiltrates. - False
True or False The best time to change the tubing is when the IV solution bag is changed. - True
True or False IV tubing sets will remain sterile for 72 hours, even when the patient is receiving blood and fat emulsions. - False
True or False IV bags should be replaced when there is 200 mL left in the bag. - False
True or False The drop factor for micro-drip tubing is 10 gtt/mL - False
True or False An IV running too slowly has the potential to clot. - True
True or False A sudden increase in the amount of solution infused may result in a patient's death.
- True
True or False IV tubing is tagged with the date and time to indicate when tubing replacement is necessary. - True
True or False Failure to prime IV tubing with solution and remove air bubbles may result in a patient's death. - True